• Optical-Fiber Side |
Fiber Connector |
SC or ST |
Fiber Cable Requirements |
|
Ring Transmission |
Half-duplex |
Point-to-Point Transmission |
Half-duplex or full-duplex |
• RS-232/422/485 Side |
Connector |
Terminal Block |
RS-232 Signals |
Tx, Rx, GND |
RS-422 Signals |
TxD+, TxD-, RxD+, RxD-, GND |
RS-485-4w Signals |
TxD+, TxD-, RxD+, RxD-, GND |
RS-485-2w Signals |
Data+, Data-, GND |
Baudrate |
50 bps to 921.6 kbps |
• Physical Characteristics |
Housing |
Metal |
Dimensions |
Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in) |
Weight |
320 g (0.71 lb) |
• Environmental Limits |
Operating Temperature |
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature |
-40 to 75°C (-40 to 167°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
• Power Requirements |
Input Voltage |
12 to 48 VDC |
Input Current |
140 mA @ 12 VDC |
Power Line Protection |
1 kV Burst (EFT), EN61000-4-4
1 kV Surge, EN61000-4-5 |
Voltage Reversal Protection |
Protects against V+/V- reversal |
Overcurrent Protection |
1.1 A (protects against two signals shorted together) |
• Standards and Certifications |
Safety |
UL 60950-1 |
EMC |
EN 55032/24 |
EMI |
CISPR 32, FCC Part 15B Class B |
EMS |
EN 61000-4-2 (ESD): Contact: 6 kV; Air: 8 kV
EN 61000-4-3 (RS): 80 MHz to 1 GHz: 10 V/m
EN 61000-4-4 (EFT): Power: 1 kV
EN 61000-4-5 (Surge): Power: 1 kV
EN 61000-4-6 (CS): 150 kHz to 80 MHz: 3 V/m
EN 61000-4-8 (PFMF) |
Green Product |
RoHS, CRoHS, WEEE |
• MTBF (mean time between failures) |
Time |
780,480 hrs |
Standard |
Telcordia (Bellcore), GB |
• Warranty |
Warranty Period |
5 years |
Details |
See www.moxa.com/warranty |